Remote Fiber Test System

FEATURES
The only real time monitoring system on the market
Unique RFTS test method for cable management with E-Map
Fault-on-map feature with GIS-based network document
24/7 detection, location and tracking of fiber degradations
Modular unit for easy operation and maintenance

RFTS is the only truly reliable monitoring solution that enables you to integrate all of your network operation and maintenance activities into one simple monitoring system.

RFTS also provides an operation interface based on GIS for mapping of fault-on-map features.

Fast Reacting
The real time alarm function will shorten time by identifying the exact source of the trouble through running remote test units (RTUs) with power monitoring at key sites across your network.
Plus, it allows you to receive alarm messages which pinpoint the faults on the map within 90 seconds. Then, the system will record the errors and produces a detailed and highly accurate report.

All-In-One Solution
RFTS can automatically track, detect and locate degradations of the network, and analyze the information as well as provide highly accurate reports including degradation type, values and location. With increasing bandwidth demands, you can extend modules directly so that you don’t have to worry about integrating new modules into your network.

Comprehensive Monitoring
Once a new fiber connection is detected, the 24/7 surveillance starts without any additional manual intervention. If there is a problem, RFTS generates a fault history for technicians to analyze and address errors.


Basic Test

RTU Chassis and Specifications on 1550nm

 Model

Specifications

FIS2156xx-D

FIS2156xx-A

FIS2157xx-D

FIS2157xx-A

Dynamic Range

@SNR=1

Pulse=20 us

40dB

40dB

50dB

50dB

AC/ DC

V

V

V

V

Racket with

17 slots

V

V

V

V

Ethernet interface

V

V

V

V

Monitoring Structure

Off-Line

On-Line

Off-Line

On-Line

1. Please contact us if you need any further information.
2. xx: the number of channel on OCS including 4, 8, 12, 16, 24
3. WDM and filter modules are necessary for On-Line.
4. The monitoring distance depends on your actual location.

RTU Chassis and Specifications on 1625nm

Model

Specifications

FIS2164xx-D

FIS2164xx-A

FIS2166xx-D

FIS2166xx-A

Dynamic Range

@SNR=1

Pulse=20 us

40dB

40dB

45dB

45dB

AC/ DC

V

V

V

V

Racket with

17 slots

V

V

V

V

Ethernet interface

V

V

V

V

Monitoring Structure

Off-Line

On-Line

Off-Line

On-Line

1. Please contact us if you need any further information.
2. xx: the number of channel on OCS including 4, 8, 12, 16, 24
3. WDM and filter modules are necessary for On-Line.
4. The monitoring distance depends on your actual location.

Real Time Test




Real Time Test

RTU Chassis and Specifications on 1550nm

   Model

Specifications

FIS2256xx-D

FIS2256xx-A

FIS2257xx-D

FIS2257xx-A

Dynamic Range

@SNR=1

Pulse=20 us

45dB

45dB

50dB

50dB

AC/ DC

V

V

V

 

Racket with

17 slots

V

V

V

V

Ethernet interface

V

V

V

V

Monitoring Structure

Off-Line

On-Line

Off-Line

On-Line

1. Please contact us if you need any further information.
2. xx: the number of channel on OCS including 4, 8, 12, 16, 24
3. WDM and filter modules are necessary for On-Line.
4. The monitoring distance depends on your actual location.

RTU Chassis and Specifications on 1625nm

Model

Specifications

FIS2264xx-D

FIS2264xx-A

FIS2266xx-D

FIS2266xx-A

Dynamic Range

@SNR=1

Pulse=20 us

40dB

40dB

45dB

45dB

AC/ DC

V

V

V

V

Racket with

17 slots

V

V

V

V

Ethernet interface

V

V

V

V

Monitoring Structure

Off-Line

On-Line

Off-Line

On-Line

1. Please contact us if you need any further information.
2. xx: the number of channel on OCS including 4, 8, 12, 16, 24
3. WDM and filter modules are necessary for On-Line.
4. The monitoring distance depends on your actual location.



BACK